Vidicons

LI101 Max.spectrum sensitivity, Angstrem 4000-5000 Resolution, lines 625 Illuminating intensity, Lux (30) -200 LI17 Max.spectrum sensitivity, Angstrem 4500-5800 Resolution, lines 625 LI201 Max.spectrum sensitivity, Angstrem 4500-5800 Resolution, lines 625 Illuminating intensity, Lux 1,3 LI202 Max.spectrum sensitivity, Angstrem 4500-5800 Resolution, lines 600 Illuminating intensity, Lux 1,3 LI203 Max.spectrum sensitivity, Angstrem 7000 Resolution, lines 900 Illuminating intensity, Lux 1,0-5,0 LI204 Max.spectrum sensitivity, Angstrem 4000-5500 Illuminating intensity, Lux 5,0-40,0 LI207 Max.spectrum sensitivity, Angstrem 4700-5700 Resolution, lines 625 Illuminating intensity, Lux 0,5-3,0 LI211 Max.spectrum sensitivity, Angstrem 4400-5500 Resolution, lines 625 Illuminating intensity, Lux 5*10e-4 - 5,0 LI212 Max.spectrum sensitivity, Angstrem 4000-5000 Resolution, lines 600 Illuminating intensity, Lux 0,1-5,0 LI212M Max.spectrum sensitivity, Angstrem 400-5000 Resolution, lines 600 Illuminating intensity, Lux 0,1-5,0 LI213 Max.spectrum sensitivity, Angstrem 4500-5800 Resolution, lines 600 Illuminating intensity, Lux 0,5 LI214 Max.spectrum sensitivity, Angstrem 4500-5500 Resolution, lines 600 Illuminating intensity, Lux 5*10e-5-5,0 LI217 Max.spectrum sensitivity, Angstrem 4000-5000 Resolution, lines 600 Illuminating intensity, Lux 5*10e-6-1*10e-2 LI218 Max.spectrum sensitivity, Angstrem 4400-5200 Resolution, lines 600 Illuminating intensity, Lux 0,3 LI218-1 Max.spectrum sensitivity, Angstrem 4400-5200 Resolution, lines 625 Illuminating intensity, Lux 1*10e-3-0,5 LI22 Resolution, lines 625 LI22-1 Resolution, lines 625 LI221 Max.spectrum sensitivity, Angstrem 4400-5000 Illuminating intensity, Lux 1,8 LI222 Max.spectrum sensitivity, Angstrem 4400-5000 Illuminating intensity, Lux 0,9 LI223 Max.spectrum sensitivity, Angstrem 4400-5000 Illuminating intensity, Lux 1,8 LI224 Max.spectrum sensitivity, Angstrem 4400-5000 Illuminating intensity, Lux 0,9 LI225 Max.spectrum sensitivity, Angstrem 4500-5250 Resolution, lines 625 Illuminating intensity, Lux 0,3 LI226 Max.spectrum sensitivity, Angstrem 4500-5250 Resolution, lines 625 LI227 Max.spectrum sensitivity, Angstrem 4400-5000 Illuminating intensity, Lux 0,6 LI227 Max.spectrum sensitivity, Angstrem 4400-5000 Illuminating intensity, Lux 1,2 LI23 Max.spectrum sensitivity, Angstrem 4200-7800 Resolution, lines 550 Illuminating intensity, Lux -100 LI230 Max.spectrum sensitivity, Angstrem 4000-5000 Resolution, lines 1000 Illuminating intensity, Lux 5*10e-7 to 1*10e-3 LI231 Max.spectrum sensitivity, Angstrem 4400-5200 Resolution, lines 450 LI231-1 Max.spectrum sensitivity, Angstrem 4400-5200 Resolution, lines 450 LI232 Max.spectrum sensitivity, Angstrem 5000 Resolution, lines 900 Illuminating intensity, Lux 0,5
Leave a request
Backward wave tubes Generator and modulator tubes Klystrons Magnetrons Noise generators Receive amplify Travelling wave tubes
Gas stabilizer Baretter
Cold cathode Thyratron Tube rectifier Thyratrons Pulse Thyratrons
Resonant spark-gaps Protective spark-gaps
Oscilloscope’s CRT Vidicons Alphanumeric CRT Storage CRT

By using this website, you agree we use essential cookies in accordance with the Privacy Policy to improve its performance