Generator and modulator tubes
G433
Type
triode
Brief application
oscillation
Cooling method
forced water
Output power
60kW
Maximum anode voltage
40kV
G807
Type
beam tetrode
Brief application
oscillation, amplification
Cooling method
air
Output power
25W
Maximum operating frequency
60MHz
Maximum anode voltage
600V
G811
Type
triode
Brief application
oscillation
Cooling method
air
Output power
40 W
Maximum operating frequency
110 MHz
Maximum anode voltage
5 kV
GI11B
Type
pulse triode
Brief application
oscillation
Cooling method
forced air
Output power
80W
Maximum operating frequency
14cm
Maximum anode voltage
0,8kV/2kV in pulse
GI12B
Type
pulse triode
Brief application
amplification, oscillation
Cooling method
forced air
Output power
80W
Maximum operating frequency
9cm
Maximum anode voltage
0,8kV/2kV in pulse
GI130M
Type
pulse triode
Brief application
oscillation
Cooling method
forced air
Output power
20W/110W in pulse
Maximum operating frequency
9cm
Maximum anode voltage
0,9kV
GI13BM
Type
pulse triode
Brief application
Oscillation
Cooling method
forced air
Output power
110W
Maximum operating frequency
9cm
Maximum anode voltage
1kV/4kV in pulse
GI14B
Type
pulse triode
Brief application
Oscillation
Cooling method
forced air
Output power
500W/100kW in pulse
Maximum operating frequency
30cm
Maximum anode voltage
21kV
GI150
Type
pulse triode
Brief application
oscillation
Cooling method
forced air
Output power
3W/100W in pulse
Maximum operating frequency
7cm
Maximum anode voltage
0,8kV/4kV in pulse
GI15B
Type
pulse triode
Brief application
oscillation
Cooling method
forced air
Output power
3W/100W in pulse
Maximum operating frequency
7cm
Maximum anode voltage
0,8kW/4kW in pulse
GI16B
Type
pulse tetrod
Brief application
oscillation, amplification
Cooling method
forced air
Output power
2,5kW/60kW in pulse
Maximum anode voltage
13,2kV
GI17
Type
pulse triode
Brief application
Oscillation
Cooling method
forced air
Output power
150W/100kW in pulse
Maximum operating frequency
500MHz
Maximum anode voltage
9kV in pulse
GI18B
Type
pulse triode
Brief application
oscillation, amplification
Cooling method
forced air
Output power
6kW
Maximum operating frequency
160kHz
Maximum anode voltage
16,5kV
GI18BM
Type
pulse triode
Brief application
oscillation, amplification
Cooling method
forced air
Output power
6kW/300kW in pulse
Maximum operating frequency
160kHz
Maximum anode voltage
16,5kV
GI19B
Type
pulse triode
Brief application
Oscillation
Cooling method
forced air
Output power
1kW/230kW in pulse
Maximum operating frequency
metric band
Maximum anode voltage
14kV
GI210
Type
pulse triode
Brief application
oscillation
Cooling method
forced air
Output power
25W/4kW in pulse
Maximum operating frequency
10cm
Maximum anode voltage
0.8kV/5kV in pulse
GI21B
Type
pulse triode
Brief application
oscillation, amplification
Cooling method
forced air
Output power
110W
Maximum operating frequency
9,5cm
Maximum anode voltage
0,8kV/5kV in pulse
GI22
Type
pulse triode
Brief application
oscillation
Cooling method
forced air
Output power
375W
Maximum operating frequency
5000MHz
Maximum anode voltage
2kV
GI23
Type
pulse triode
Brief application
oscillation, amplification
Cooling method
forced air
Output power
300W/40kW in pulse
Maximum operating frequency
28cm
Maximum anode voltage
1,3kV/14kV in pulse
GI24A
Type
pulse triode
Brief application
amplification
Cooling method
forced water
Output power
25kW/1000kW in pulse
Maximum operating frequency
170MHz
Maximum anode voltage
27kV
GI25
Type
pulse triode
Brief application
oscillation
Cooling method
forced air
Output power
1200W
Maximum operating frequency
5400MHz
Maximum anode voltage
3kV in pulse
GI26A
Type
pulse triode
Brief application
amplification
Cooling method
forced water
Output power
60kW/11MW in pulse
Maximum operating frequency
25MHz
Maximum anode voltage
30kV
GI26B
Type
pulse triode
Brief application
amplification
Cooling method
forced air
Output power
20kW/3MW in pulse
Maximum operating frequency
25MHz
Maximum anode voltage
30kV
GI27A
Type
pulse triode
Brief application
oscillation, amplification
Cooling method
forced water
Output power
25kW/4MW in pulse
Maximum operating frequency
150MHz
Maximum anode voltage
40kV
GI27A-1
Type
pulse triode
Brief application
oscillation, amplification
Cooling method
forced water
Output power
25kW/5MW in pulse
Maximum operating frequency
150MHz
Maximum anode voltage
40kV
GI2A
Type
pulse beam tetrode
Brief application
amplification
Cooling method
forced water
Maximum anode voltage
66kV
GI3
Type
pulse triode
Brief application
oscillation
Cooling method
air
Output power
10W
Maximum operating frequency
300MHz
Maximum anode voltage
2,8kV
GI30
Type
double pulse beam tetrode
Cooling method
air
Maximum anode voltage
5kV
GI31
Type
pulse triode
Brief application
oscillation
Cooling method
air
Output power
12W/1,5kW in pulse
Maximum operating frequency
2100MHz
Maximum anode voltage
2,8kV
GI31R
Type
pulse triode
Brief application
oscillation
Cooling method
forced air
Output power
12W/1,2kW in pulse
Maximum operating frequency
7cm
Maximum anode voltage
2,8kV